好看日韩在线视频免费,日本不卡一区二区三区,三级a全过程在线观看,亚洲精品国产9999久久久久

技術(shù)中心

Human VDR 人*受體(VDR)

2013年12月16日 13:29:25人氣:122來(lái)源:上海蔚霆生物科技有限公司

資料類型doc文件資料大小99840
下載次數(shù)8資料圖片 【點(diǎn)擊查看】
上 傳 人上海蔚霆生物科技有限公司 需要積分0
關(guān) 鍵 詞Human VDR ,人維生素,D受體(VDR)
【資料簡(jiǎn)介】

 

Human VDR ELISA Kit

For the quantitative in vitro determination of Human Vitamin D Receptor concentrations in

 serum - plasma - celiac fluid - tissue homogenate - body fluid

 

 

 

 

 

 

 

 

FOR LABORATORY RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

 

 

This package insert must be read in its entirety before using this product.

 

ELISA

ENZYME LINKED IMMUNOSORBENT ASSAY

INTENDED USE AND TEST PRINCIPLE

This VDR ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of VDR in the sample, this VDR ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus VDR concentration. The concentration of VDR in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4 before centrifugation for 20 minutes at approximay 2000×g. Remove serum and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

 

MATERIALS REQUIRED BUT NOT SUPPLIED

1.  37 ℃ incubator

2.  Standard microplate reader capable of measuring absorbance at 450 nm

3.  Precision pipettes, disposable pipette tips and Absorbent paper

4.  Distilled or deionized water

 

REAGENTS PROVIDED

All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

 

Name

96 determinations

48 determinations

Microelisa stripplate

12*8strips

12*4strips

Standard6 vial

0.5ml/vial

0.5ml/vial

Sample diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20X Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

Stop Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note:

1.  Standard concentration was followed by: 40、20、10、5、2.5、1.25ng/ml

2.  If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

 

PRECAUTIONS

1.         Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.

2.         Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.

3.         Do not use kit components beyond their expiration date.

4.         Use only deionized or distilled water to dilute reagents.

5.         Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.

6.         Use fresh disposable pipette tips for each transfer to avoid contamination.

7.         Do not mix acid and sodium hypochlorite solutions.

8.         Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.

9.         All samples should be disposed of in a manner that will inactivate viruses.

10.     Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.

11.     Substrate Solution is easily contaminated. If bluish prior to use, do not use.

12.     Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.

13.     Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

 

REAGENT PREPARATION AND STORAGE

Wash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.

 

ASSAY PROCEDURE

1.  Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.

2.  Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.

3.  Add 10l of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.

4.  Wash the Microtiter Plate 4 times.

Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well compley with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.

Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.

5.  Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

6.  Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.

7.  Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

 

CALCULATION OF RESULTS

1.         This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.

2.         First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.

3.         To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.

4.         Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.

5.         Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.

6.         Assay range: 1.25 ng/ml –40 ng/ml.

7.  Sensitivity: The minimum detectable dose of Human VDR is typically less than 1.0 ng/ml.

8.  Cross-reactivity: This assay recognizes recombinant and natural Human VDR. No significant cross-reactivity or interference was observed.

9.  Storage: 2-8℃ (Use frequently); six months (-20℃)。

10.  Standard curve

 

 

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

 上海逸晗生物科技有限公司代理不同品牌價(jià)格檔次的ELISA試劑盒??贵w產(chǎn)品等, 品種多,質(zhì)量好,價(jià)格實(shí)惠,并且還提供免費(fèi)代檢測(cè)服務(wù)。
本公司的更多產(chǎn)品,請(qǐng)點(diǎn)擊公司:http://www.yihanbio.com/

上海蔚霆生物科技有限公司作者

上一篇:德國(guó)ROSENBERG風(fēng)機(jī)DKHR450-4K

下一篇:德國(guó)BRECO同步帶100BATK10-1250-PAZ-BFX


我要投稿
  • 投稿請(qǐng)發(fā)送郵件至:(郵件標(biāo)題請(qǐng)備注“投稿”)hbzhan@vip.qq.com
  • 聯(lián)系電話0571-87759680
環(huán)保行業(yè)“互聯(lián)網(wǎng)+”服務(wù)平臺(tái)
環(huán)保在線APP

功能豐富 實(shí)時(shí)交流

環(huán)保在線小程序

訂閱獲取更多服務(wù)

微信公眾號(hào)

關(guān)注我們

抖音

環(huán)保在線網(wǎng)

抖音號(hào):hbzhan

打開(kāi)抖音 搜索頁(yè)掃一掃

視頻號(hào)

環(huán)保在線

公眾號(hào):環(huán)保在線

打開(kāi)微信掃碼關(guān)注視頻號(hào)

快手

環(huán)保在線

快手ID:2537047074

打開(kāi)快手 掃一掃關(guān)注
意見(jiàn)反饋
国产成人无码AV一区二区三区| 日韩人妻无码中字一区二区| 鸡巴抽插逼逼视频| 色男人天堂亚洲男人天堂| 日韩一区二区三区国色天香| 涩涩屋操美女视频| 91久国产在线观看| 肏亚洲女人小骚逼| 久久99热人妻偷产精品| 老司机精品成人无码AV| 日本精品高清在线观看| 夜夜嗨av少妇一二三区| 国产精品操大屁股老淑女| 女人日比比视频免费| 日本入室强伦姧人妻中文| 真人作爱免费视频| 久久国产老熟女老女人| 中文字幕一区二区三区中文字幕| 国产一区二区三区免费观在线| 综合伊人久久在一二三区| 操鸡巴奶子在线观看| 大黑屌爆操日本女人| 亚洲免费福利视频| 啊啊啊好疼视频进来| 日韩无码av三级片| 日韩有码视频在线| 福利国产第一视频| 老色鬼精品视频二区三区| 日本不卡高清视频在线播放| 粉嫩小穴被大鸡巴操视频在线观看| 波多野吉衣一区在线观看| 国产精品三级一区二区| 在线观看日韩欧美| 丰满少妇被强入在线观看| 国产欧美日韩一区二区在线观看| 日本免费一区二区在线| 麻豆视频一级片在线观看| 欲色福利网免费在线播放| 日韩欧美人妻综合| 亚洲国际精品一区二区| 免费女人男人肏逼|